Send documentation feedback to HP Close We welcome your comments! What would you recommend for Data Protector 6.20? If the user does not have this permission, the session cannot be started. This happens when an application on the disk image leaves some patterns on the disk image. http://homeshareware.com/cannot-connect/cannot-connect-to-media-agent-on-system-ipc-cannot-connect.html

Action Configure the protection for your full backups so that they are protected for longer than your incremental backups. It is recommended to use server editions of Windows for systems involved in intensive backup operations, such as the Cell Manager, Media Agent clients, application agent clients, file servers, and so And imported the server into the cell manager (windows server). By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner https://community.hpe.com/t5/Data-Protector-Practitioners/Cannot-connect-to-Media-Agent-port-20026-IPC-Cannot-Connect/td-p/4776457

Ipc Cannot Connect Data Protector

This DB size is around 2.0TB where i can backup only 300GB in first two hours then backup fails. If you restore from such a backup, some or all the files may not be restored correctly. However the actual dataflow is done on a lot of other dynamically assigned ports for that session in the highend range like 10000 and above.. 0 Kudos Reply Jan Soska Honored

The time now is 06:00 PM. 2016 Micro Focus HOME | SEARCH | REGISTER RSS | MY ACCOUNT | EMBED RSS | SUPER RSS | Contact Us | Data Protector DP Server - restart Data Protector ### Stop Data Protector [[email protected] server]# /opt/omni/sbin/omnisv -stop ### Start Data Protector [[email protected] server]# /opt/omni/sbin/omnisv -start ### Check Status of Data Protector [[email protected] server]# /opt/omni/sbin/omnisv run a daily backup with error below. Also check if maybe other Applications listen to the Ports within that Range.On our site Tivoli Monitoring used part of the same Range, causing havoc until we separated them. 0 Kudos

How does the client's port config look? Ipc Cannot Connect System Error 10060 Connection Timed Out All times are GMT2. Action Obtain information on available licenses by running: omnicc -check_licenses -detail Request new licenses and apply them. Wiki Webinars FAQ Advanced Search Forum PRODUCT RELATED DISCUSSIONS FILE & NETWORKING SERVICES Open Enterprise Server OES: NetWare OES-NW: Server Backup HP Data Protector backing up NetWare servers You can view

Create the Change Log Provider database link for the shared volume on all cluster nodes on which incremental backups are performed after a cluster failover. See also Scheduled sessions no longer run Problem Scheduled sessions no longer run since the Data Protector system account, which is supposed to start scheduled sessions, is not in the Admin Related task The media in the device are different from those in the preallocation list Problem The media in the device are formatted but are different from those in the preallocation Jansen Trusted Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎04-12-2011 11:31 PM ‎04-12-2011 11:31 PM Re: Cannot

  1. Action To make sure that incremental backups are correctly performed, create a symbolic link of the Change Log Provider database to a separate cluster shared volume as follows: Select a shared
  2. Name resolution works?
  3. Therefore, a full backup is performed.

Ipc Cannot Connect System Error 10060 Connection Timed Out

In case of the Data Protector cluster Cell Manager, you can choose the Data Protector shared disk. When I executed the backup specification, it failed.   Error message like the following: [Major] From [email protected] Virtual machine '/vm/myVMname': no target host [Major] From [email protected] Lost connection to OB2BAR Backup Ipc Cannot Connect Data Protector This Guide can also be downloaded fromhttp://support.openview.hp.com/selfsolve/document/KM532906?searchIdentifier=-7ba5f919%3a14336a1f354%3a6ed8&resultType=document&documentURL=KM532906&resultsURL=%2fselfsolve%2fmanuals&allowReturn=true&searchString=&searchKey=2014-01-01+03%3a52%3a01Someone else suggested using OB2PORTRANGESPEC, while this will work just as well, I find it to be overly complicated, and hardly ever use it 0 You may have to register before you can post: click the register link above to proceed.

Action Set up the TCP/IP protocol and configure DNS properly. have a peek at these guys By default, this option is set to 1. The new enhanced incremental backup repository will be created and you will be able to perform enhanced incremental backups. and not the 28th   -full -every         -day 31 -month May Jul Aug Oct Dec Jan Mar         -at 21:00   -full -every         -day 30 -month Jun Sep Nov

This thread has been  moved from Tape > Tape Backup (Small and Medium Business) > to Data Protector Support and News Forum. -Hp Forum Moderator

0 0 07/25/13--20:11: Data protector 6.20 The backup owner is different Problem If your backups are configured to run as private, the user starting the backup is the owner of the data. Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small check over here This user will become the owner of all backups based on this backup specification, regardless of who actually starts the backup session.

There are two possible reasons for this: You have changed the trees in the backup specification of the protected full backup. We are quite sure there was no firewall change on linux host where media agent runs.HP support say reconfigure portrange and update firewall, but it seems to me DP can use Backup protection expiration Problem When scheduling backups, you have set the same protection period for full and incremental backups, which means that incremental backups are protected for the same duration as

To open the configured email client on this computer, open an email window.

Jansen Trusted Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎05-30-2011 11:02 PM ‎05-30-2011 11:02 PM Re: Cannot If any of these three values changes, Data Protector considers it as a new backup object and performs a full backup instead of an incremental. Contact us about this article i have the following schedule which does a full backup on the last day of every month. So i have installed the disk agent and media agent version 6.2 in linux server.

I can see it reads about 2 GB and then takes a 10 min break (writing to tape?). These types of errors tell us there was a network problem during the backup that prevented Data Protector from maintaining an open connection between the cell server, disk and media agents, Action Install the IIS 6 Metabase Compatibility component under IIS 6 Management Compatibility and restart the backup. this content I have it running on a Win 2003 server and does great when I want to backup another Windows box, fairly painless.

To start viewing messages, select the forum that you want to visit from the selection below. If you want to change the default 'Backup latency interval', you could do so by adding the following registry key.'Backup latency interval' (days) registry key:System\CurrentControlSet\Services\NTDS\Parameters\Backup Latency Threshold (days)   Any one Asynchronous reading does not improve backup performance Problem With the Asynchronous reading (Windows specific) option selected in the backup specification, there is no backup performance improvement, or there may even be Action Create more space on the disk where the file library is located: Free some space on the disk where the files are being backed up.

I moved over to one of our Service Guard clustered servers and I am getting the following error:   [Warning] From: [email protected] "SMISA" Time: 7/26/2013 9:36:42 AMThe following CLI command has